Government Tender for 66kV Substation LILO Erection Work in Amreli - Power & Energy Sector
This government tender offers an excellent opportunity for electrical contractors specializing in power transmission to participate in the **erection of LILO connections at 66kV substations** in Gujarat. The project involves connecting the existing Sagapara-Timana line to the Thadach substation, enhancing regional power infrastructure under the **R&M scheme 2025-26**. Bidders must meet strict eligibility criteria, including valid licenses, experience, and financial stability. The tender process is conducted electronically via the NProcure portal, ensuring transparency and efficiency. With a project duration of 180 days and an estimated value of over 51 lakh INR, this tender is ideal for firms with proven expertise in transmission line erection, tower installation, and conductor stringing. Interested companies should review detailed specifications, prepare required documents, and submit their bids before the deadline to secure this lucrative government contract in Gujarat’s power sector.
Details
Financial
Technical
Tender Configuration
Scope of Work
The scope of work includes:
- Erection of tower structures for the LILO connection at 66kV Thadach substation.
- Installation of ACSR Panther conductors along the 3.91 Rkm corridor.
- Stringing and tensioning of conductors ensuring compliance with technical standards.
- Testing and commissioning of the newly installed line.
- Adherence to safety protocols and quality standards throughout the project.
Key deliverables:
- Complete erection of towers and conductors.
- Proper grounding and insulation checks.
- Submission of test reports and commissioning certificates.
Process steps:
- Site preparation and foundation work.
- Tower erection and alignment.
- Conductor installation and stringing.
- Final testing and commissioning.
Technical Specifications
The technical specifications for the project include:
Parameter | Specification |
---|---|
Tower Type | Steel lattice towers suitable for 66kV lines |
Conductor | ACSR Panther, conforming to IEC standards |
Line Length | Approx. 3.91 Rkm |
Insulation | Appropriate insulators and grounding systems |
Testing | Line insulation testing, conductor tension checks |
Safety | Compliance with Indian electrical safety standards |
Financial Requirements
The estimated project cost is approximately 51.19 lakh INR, with a bid security (EMD) of 80,000 INR. The financial proposal should include:
Cost Element | Amount (INR) |
---|---|
Total Estimated Cost | 5,118,897.94 |
Bid Security (EMD) | 80,000 |
Payments will be released based on milestone achievement and submission of valid invoices and test reports. All financial transactions are subject to applicable taxes as per government norms.
Evaluation Criteria
Bids will be evaluated based on:
Criteria | Weightage |
---|---|
Technical competence and experience | 50% |
Financial stability and cost | 30% |
Past project performance | 20% |
Categories
Industry & Sector Information
Primary Industry
Sectors
Related Industries
Target Audience
Tender Documents
1 DocumentTender Stages
Tender Stages
stage name | evaluation date | minimum forms for submission |
---|---|---|
Preliminary Stage | 16-09-2025 17:00 | 0 |
Commercial Stage | 16-09-2025 17:30 | 0 |
Probable Bidders
Ultimate Power Pack
🎯 Unlimited Downloads
Download ANY tender document instantly - No limits!
📊 AI Analytics Dashboard
Professional insights & competitor intelligence
🎁 BONUS FEATURES
Similar Business Opportunities
5 similar tenders found • 1 urgent
Tender for the Work of Erection, testing and commissioning of 66KV LILO at 66KV Ranpur (Dhamalpar) S/S from existing 66KV Navagam-Kuvadva line partly on D/C tower with ACSR Panther Conductor.
Erection work of 66KV Sarol LILO line from Exi. 66KV Vatadara-Ras line on D/C Panther tower with ACSR Panther Conductor having length 17 Km under Nadiad construction division under Nadiad Circle.
Erection work of 66kV D/C line from proposed 220kV Avaniya S/S to existing 66kV Mamsa S/S partly on M/C and D/C tower with AL-59 conductor (equivalent weight of ACSR Panther conductor) having approx. length of 11.00 Rkm {Overhead Portion only}(Tal.:Ghogha, Dist.:Bhavnagar).
Frequently Asked Questions
The bid submission deadline is 16th September 2025 at 4:00 PM. Bidders must submit all required documents and bids online before this time to be considered for evaluation.
Eligible bidders must have valid electrical contractor licenses, GST registration, experience in transmission line erection, and financial stability demonstrated through bank solvency certificates and recent financial statements. Additional requirements include past project experience and compliance with safety standards.
Tender documents are available for free download from the official NProcure portal. Bidders must register on the portal, procure a valid Digital Certificate, and follow the instructions for downloading and submitting bids electronically.
The project must comply with Indian electrical safety standards, IEC standards for conductors and insulators, and GETCO specifications for tower erection and conductor stringing. All testing and commissioning must meet prescribed norms, with detailed reports submitted for approval.
All clarifications should be directed to Superintending Engineer, GETCO, Circle Office, Amreli via email at [email protected] or phone at +91-79-40007517. Support for online bidding can be obtained from (n)Code Solutions support team.